HbA1c Analyzer (Ion-Exchange HPLC)糖化血红蛋白分析仪(离子交换 HPLC)
- Method
- Cation-exchange HPLC
- Measuring range
- 3.0–20.0% HbA1c (NGSP)
诊断分析仪

Photo for reference; configuration may vary by order.
Model No. DIA-0001 · Diagnostic Laboratory Equipment
血气电解质分析仪
Critical care, theatre and neonatal teams need acid-base and electrolyte status fast. Using 65–100 µL of whole blood drawn from an artery, vein or capillary, this analyzer reports in 45–90 seconds. Ranges include pH 6.500–8.000, pCO2 5–250 mmHg, pO2 0–800 mmHg, Na+ 85–200 mmol/L and K+ 1.0–12.0 mmol/L.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Critical care, theatre and neonatal teams need acid-base and electrolyte status fast. Using 65–100 µL of whole blood drawn from an artery, vein or capillary, this analyzer reports in 45–90 seconds. Ranges include pH 6.500–8.000, pCO2 5–250 mmHg, pO2 0–800 mmHg, Na+ 85–200 mmol/L and K+ 1.0–12.0 mmol/L.
| Parameter | Value |
|---|---|
| Sample volume 样本量 | 65–100 µL |
| Analysis time 分析时间 | 45–90 s |
| pH range pH 范围 | 6.500–8.000 |
| pCO2 range pCO2 范围 | 5–250 mmHg |
| pO2 range pO2 范围 | 0–800 mmHg |
| Na+ range Na+ 范围 | 85–200 mmol/L |
| K+ range K+ 范围 | 1.0–12.0 mmol/L |
| Sample types 样本类型 | Arterial, venous and capillary whole blood |
| Calibration 校准 | Automatic, 1-point and 2-point |
| Data storage 数据存储 | ≥ 10,000 results |
| Model No. | DIA-0001 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.