Class III Glovebox Biosafety CabinetIII 级手套箱生物安全柜
- Cabinet class
- Class III
- Negative pressure
- 100–200 Pa below room
III 级生物安全柜

Photo for reference; configuration may vary by order.
Model No. CLN-0004 · Biosafety Cabinets
III 级厌氧手套箱安全柜
Strict anaerobes and microbiome samples need oxygen at 5 ppm or below, down to 1 ppm, inside a contained box. A heated palladium catalyst maintains N2 or N2/H2/CO2 atmosphere, while the cabinet stays 100–200 Pa below room with double H14 exhaust. A buffer chamber handles transfers.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Strict anaerobes and microbiome samples need oxygen at 5 ppm or below, down to 1 ppm, inside a contained box. A heated palladium catalyst maintains N2 or N2/H2/CO2 atmosphere, while the cabinet stays 100–200 Pa below room with double H14 exhaust. A buffer chamber handles transfers.
| Parameter | Value |
|---|---|
| Cabinet class 柜体级别 | Class III anaerobic |
| Oxygen level 氧含量 | ≤ 5 ppm, down to 1 ppm |
| Atmosphere 气氛 | N2 or N2/H2/CO2 mix |
| Negative pressure 负压 | 100–200 Pa below room |
| Exhaust filtration 排风过滤 | Double HEPA H14 |
| Catalyst 催化剂 | Palladium, heated |
| Transfer port 传递口 | Double door with buffer chamber |
| Glove ports 手套口 | 2–4, long gauntlet |
| Humidity control 湿度控制 | Set to avoid condensation |
| Gas analyser 气体分析仪 | O2 and H2 sensors |
| Model No. | CLN-0004 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.