电感耦合等离子体发射光谱仪

ICP-OES

Model No. ICO-0003 · ICP Spectrometers

Dual-View ICP-OES Spectrometer

双向观测电感耦合等离子体发射光谱仪

Busy labs that see ultratrace water one hour and high-matrix digests the next can let this instrument pick the view per element. Axial mode gives typical limits of 0.1–2 µg/L, radial mode tolerates up to 20% dissolved solids, and switching is automatic. RF power runs from 1000 to 1600 W. Ideal where one ICP must do everything.

Wavelength range
165–900 nm
Viewing modes
axial and radial, switchable
Detection limit (axial)
0.1–2 µg/L typical
Detection limit (radial)
1–20 µg/L typical
Dissolved solids tolerance
up to 20% (radial)
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Busy labs that see ultratrace water one hour and high-matrix digests the next can let this instrument pick the view per element. Axial mode gives typical limits of 0.1–2 µg/L, radial mode tolerates up to 20% dissolved solids, and switching is automatic. RF power runs from 1000 to 1600 W. Ideal where one ICP must do everything.

Highlights

  • Automatic view selection element by element
  • Trace and major elements in the same run
  • Wider concentration range without extra dilutions
  • One instrument replaces two dedicated systems

Applications

  • Environmental samples across wide concentration ranges
  • Pharmaceutical impurity and assay testing
  • Food and agricultural multi-element analysis
  • Industrial and metallurgical quality control

Specifications 技术参数

ParameterValue
Wavelength range 波长范围 165–900 nm
Viewing modes 观测方式 axial and radial, switchable
Detection limit (axial) 检出限(轴向) 0.1–2 µg/L typical
Detection limit (radial) 检出限(径向) 1–20 µg/L typical
Dissolved solids tolerance 溶解固体耐受 up to 20% (radial)
Detector 检测器 CCD or CMOS array
View selection 观测选择 automatic per element
RF power 射频功率 1000–1600 W
Argon consumption 氩气消耗 14–20 L/min
Simultaneous elements 同时测定元素数 up to 70
Model No.ICO-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

USP <730> Plasma Spectrochemistry USP <233> Elemental Impurities — Procedures ICH Q3D Elemental Impurities ISO 11885 Water quality — ICP-OES determination of elements US EPA Method 200.7 ASTM D5185 ISO/IEC 17025

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Dual-View ICP-OES Spectrometer (ICO-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.