Formulators checking whether an emulsion, latex or coagulant dose will stay stable can measure zeta potential from −500 to +500 mV on this ELS analyzer. It also sizes particles from 3 nm to 100 µm. Samples up to 200 mS/cm conductivity are accepted, using a capillary cell from 0.75 mL. Temperature control covers 0–90 °C.

Size range
3 nm–100 µm
Zeta potential range
−500 to +500 mV
Mobility range
±20 µm·cm/V·s
Laser
633 nm, ≥ 4 mW
Electric field
Up to 150 V/cm, alternating
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Formulators checking whether an emulsion, latex or coagulant dose will stay stable can measure zeta potential from −500 to +500 mV on this ELS analyzer. It also sizes particles from 3 nm to 100 µm. Samples up to 200 mS/cm conductivity are accepted, using a capillary cell from 0.75 mL. Temperature control covers 0–90 °C.

Highlights

  • Zeta potential range of −500 to +500 mV
  • Combined particle sizing from 3 nm to 100 µm
  • Handles conductivity up to 200 mS/cm
  • Capillary cell needs only 0.75 mL

Applications

  • Emulsion and suspension stability screening
  • Polymer latex charge characterisation
  • Water treatment coagulant dosing studies
  • Clay and mineral dispersions
  • Pharmaceutical nanosuspensions

Specifications 技术参数

ParameterValue
Size range 粒径范围 3 nm–100 µm
Zeta potential range Zeta 电位范围 −500 to +500 mV
Mobility range 迁移率范围 ±20 µm·cm/V·s
Laser 激光器 633 nm, ≥ 4 mW
Electric field 电场 Up to 150 V/cm, alternating
Conductivity range 电导率范围 0–200 mS/cm
Temperature range 温度范围 0–90 °C
Minimum sample volume 最小样品量 0.75 mL (capillary cell)
Accuracy 准确度 ± 10% on transfer standard
Measurement time 测量时间 ≈ 2–3 min
Model No.ZPA-0001
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 13099-1 ISO 13099-2 ISO 13099-3 ASTM D4187 GB/T 32671 ISO 13320

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Electrophoretic Light Scattering Zeta Potential Analyzer (ZPA-0001)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.