石墨炉原子吸收光谱仪

Graphite Furnace AAS

Model No. GFA-0002 · Atomic Absorption Spectrometers

End-Heated Graphite Furnace Atomic Absorption Spectrometer

端部加热石墨炉原子吸收光谱仪

Routine trace metals in drinking water, effluent and food screening rarely need the most advanced furnace design. This end-heated model reaches 2800–3000 °C at up to 1500 °C/s, offers deuterium or Zeeman correction and achieves typical limits of 0.01–1 µg/L. Argon purge runs at 200–300 mL/min. A cost-effective entry point to µg/L-level work.

Atomizer
end-heated graphite tube
Maximum temperature
2800–3000 °C
Heating rate
up to 1500 °C/s
Detection limit
0.01–1 µg/L typical
Background correction
deuterium or Zeeman
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Routine trace metals in drinking water, effluent and food screening rarely need the most advanced furnace design. This end-heated model reaches 2800–3000 °C at up to 1500 °C/s, offers deuterium or Zeeman correction and achieves typical limits of 0.01–1 µg/L. Argon purge runs at 200–300 mL/min. A cost-effective entry point to µg/L-level work.

Highlights

  • Lower purchase cost for routine trace programmes
  • Background correction chosen to match your matrices
  • Platform available as an option for difficult samples
  • Modest argon use of 200–300 mL/min

Applications

  • Routine trace metals in drinking water
  • Environmental water and soil digests
  • Food lead and cadmium screening
  • Industrial effluent monitoring

Specifications 技术参数

ParameterValue
Atomizer 原子化器 end-heated graphite tube
Maximum temperature 最高温度 2800–3000 °C
Heating rate 升温速率 up to 1500 °C/s
Detection limit 检出限 0.01–1 µg/L typical
Background correction 背景校正 deuterium or Zeeman
Sample volume 样品体积 5–50 µL
Platform 平台 optional
Purge gas 保护气 argon, 200–300 mL/min
Tube life 石墨管寿命 200–1000 firings
Autosampler positions 自动进样器位 60–120 vials
Model No.GFA-0002
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

Ph. Eur. 2.2.22 Atomic absorption spectrometry USP <852> Atomic Absorption Spectroscopy US EPA Method 7010 Graphite furnace atomic absorption spectrophotometry ISO 15586 Water quality — Determination of trace elements by graphite furnace AAS ICH Q2(R2) Validation of analytical procedures IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: End-Heated Graphite Furnace Atomic Absorption Spectrometer (GFA-0002)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.