Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

光谱仪

Spectrometers

Model No. SPO-0003 · Chemical Analysis Equipment

Flame and Graphite Furnace Atomic Absorption Spectrometer

火焰与石墨炉原子吸收光谱仪

If you only need one or a few metals — Pb, Cd, As in food, Cu and Zn in leach solutions, Na and K in brine — AAS is the economical route. This unit combines air–acetylene and N2O–acetylene flame with a graphite furnace reaching 3000 °C. Flame Cu limit is ≤ 0.01 mg/L; furnace Cd reaches ≤ 0.002 µg/L.

Wavelength range
190–900 nm
Spectral bandwidth
0.2, 0.4, 0.7, 1.3 nm
Lamp positions
4 to 8 (turret)
Background correction
Deuterium lamp / Zeeman
Flame types
Air–acetylene, N2O–acetylene
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

If you only need one or a few metals — Pb, Cd, As in food, Cu and Zn in leach solutions, Na and K in brine — AAS is the economical route. This unit combines air–acetylene and N2O–acetylene flame with a graphite furnace reaching 3000 °C. Flame Cu limit is ≤ 0.01 mg/L; furnace Cd reaches ≤ 0.002 µg/L.

Highlights

  • Flame and graphite furnace on one instrument
  • Deuterium or Zeeman background correction options
  • Turret with 4 to 8 lamp positions
  • Bandwidths 0.2, 0.4, 0.7 and 1.3 nm selectable

Applications

  • Lead, cadmium and arsenic in water and food
  • Copper, zinc and iron in mining solutions
  • Trace metals in fertilizer and soil extracts
  • Sodium and potassium in industrial brines
  • Metals in electroplating baths

Specifications 技术参数

ParameterValue
Wavelength range 波长范围 190–900 nm
Spectral bandwidth 光谱带宽 0.2, 0.4, 0.7, 1.3 nm
Lamp positions 灯位数量 4 to 8 (turret)
Background correction 背景校正 Deuterium lamp / Zeeman
Flame types 火焰类型 Air–acetylene, N2O–acetylene
Flame detection limit (Cu) 火焰检出限(Cu) ≤ 0.01 mg/L
Furnace detection limit (Cd) 石墨炉检出限(Cd) ≤ 0.002 µg/L
Furnace temperature 石墨炉温度 Ambient to 3000 °C
Furnace sample volume 石墨炉进样量 5–50 µL
Precision 精密度 RSD ≤ 1% (flame), ≤ 3% (furnace)
Model No.SPO-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ASTM E415 ASTM E1019 ISO 15350 ASTM D4294 ISO 8754 ASTM D5185 ISO 11885 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Flame and Graphite Furnace Atomic Absorption Spectrometer (SPO-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.