Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

细胞计数仪

Cell Counters

Model No. CEC-0004 · Cell Biology Equipment

Flow Cytometry Cell Counter

流式细胞计数仪

When an absolute count must sit alongside marker and viability data, a bead-referenced flow counter does both in one run. Labs enumerating lymphocyte subsets or dosing cell therapy products use it to get concentration within ±5–10% of reference. The 488 nm laser is standard; add 405 or 640 nm lines if your panel needs them.

Reference beads
Known concentration suspension added in fixed volume
Fluorescence channels
4–12 (instrument dependent)
Counting accuracy
within ±5–10% of reference method
Concentration range
approx. 1 x 10³–1 x 10⁷ cells/mL
Sample volume
50–500 µL per acquisition
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

When an absolute count must sit alongside marker and viability data, a bead-referenced flow counter does both in one run. Labs enumerating lymphocyte subsets or dosing cell therapy products use it to get concentration within ±5–10% of reference. The 488 nm laser is standard; add 405 or 640 nm lines if your panel needs them.

Highlights

  • Absolute counts and phenotype from the same acquisition
  • 4–12 fluorescence channels depending on configuration
  • Up to 10,000 events per second acquisition
  • Carry-over under 1% with the validated wash routine

Applications

  • Lymphocyte subset enumeration
  • Immunophenotyping with absolute counts
  • Cell therapy product characterisation
  • Viability-adjusted cell dosing calculations

Specifications 技术参数

ParameterValue
Reference beads 参考微球 Known concentration suspension added in fixed volume
Fluorescence channels 荧光通道 4–12 (instrument dependent)
Counting accuracy 计数准确度 within ±5–10% of reference method
Concentration range 浓度范围 approx. 1 x 10³–1 x 10⁷ cells/mL
Sample volume 样品体积 50–500 µL per acquisition
Acquisition rate 采集速度 up to 10,000 events per second
Lasers 激光器 488 nm standard, optional 405 or 640 nm
Carry-over 残留 below 1% with validated wash procedure
Data output 数据输出 FCS files with absolute count reports
Dimensions (W x D x H) 外形尺寸(宽 x 深 x 高) approx. 500 x 600 x 600 mm
Model No.CEC-0004
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 20387 ISO 15189 IEC 61010-1 IEC 60825-1 USP <1046> ISO 17025

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: Flow Cytometry Cell Counter (CEC-0004)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.