Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

气相色谱质谱联用仪

GC-MS

Model No. GCM-0003 · Mass Spectrometry Instruments

GC-TOF MS System

气相色谱飞行时间质谱仪(GC-TOF MS)

Non-targeted screening, GC×GC and metabolomics need full spectra acquired fast enough for very narrow peaks. Acquiring as many as 500 spectra each second over m/z 10–1500, this GC-TOF offers resolution from unit to 25000 FWHM depending on model and ≤5 ppm mass accuracy on high-resolution versions. OFN detection is ≤20 fg. Tell us whether you need accurate mass.

Mass range
m/z 10–1500
Acquisition rate
up to 500 spectra/s
Mass resolution
1000 (unit) to 25000 FWHM, model dependent
Mass accuracy
≤ 5 ppm (high-resolution models, internal lock)
Instrument detection limit (OFN, 1 pg/µL)
≤ 20 fg (typical)
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Non-targeted screening, GC×GC and metabolomics need full spectra acquired fast enough for very narrow peaks. Acquiring as many as 500 spectra each second over m/z 10–1500, this GC-TOF offers resolution from unit to 25000 FWHM depending on model and ≤5 ppm mass accuracy on high-resolution versions. OFN detection is ≤20 fg. Tell us whether you need accurate mass.

Highlights

  • Full-spectrum data allow retrospective searching
  • Fast acquisition supports GC×GC peaks
  • High-resolution models confirm elemental formulae
  • Suited to petroleum and aroma profiling

Applications

  • Comprehensive two-dimensional GC (GC×GC) profiling
  • Metabolomics of volatile and derivatized metabolites
  • Petroleum and fuel composition analysis
  • Non-targeted environmental screening
  • Flavor, aroma and off-odor investigation

Specifications 技术参数

ParameterValue
Mass range 质量范围 m/z 10–1500
Acquisition rate 采集速率 up to 500 spectra/s
Mass resolution 质量分辨率 1000 (unit) to 25000 FWHM, model dependent
Mass accuracy 质量准确度 ≤ 5 ppm (high-resolution models, internal lock)
Instrument detection limit (OFN, 1 pg/µL) 仪器检出限(OFN,1 pg/µL) ≤ 20 fg (typical)
Linear dynamic range 线性动态范围 10^4–10^5
Ionization modes 电离模式 EI; optional CI
Ion source temperature 离子源温度 150–350 °C
Drift tube length 飞行管长度 ~0.5–1.3 m (model dependent)
Vacuum pumping 真空泵 Turbomolecular, 2 or 3 stages
Model No.GCM-0003
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

EPA Method 8270 EPA Method 524.2 EPA Method 8260 ASTM D5769 USP <467> Residual Solvents ISO 11423 EN 15662 ISO/IEC 17025 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: GC-TOF MS System (GCM-0003)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

5 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.