Automated Amino Acid Analyzer自动氨基酸分析仪
- Detection limit
- approx. 5–50 pmol per amino acid
- Separation
- Ion exchange or reversed-phase column
蛋白质分析仪

Photo for reference; configuration may vary by order.
Model No. PAN-0004 · Protein Analysis Equipment
表面等离子共振分析仪
Antibody kinetics, biosimilar binding and fragment screening need label-free, real-time interaction data. This SPR analyzer offers 1–8 flow channels or arrays, affinities from about 1 mM to 10 pM, association rates of 10^3–10^7 M⁻¹s⁻¹ and baseline noise below 0.1 RU. It controls 4–40 °C within ±0.1 °C at 1–100 µL/min flow.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Antibody kinetics, biosimilar binding and fragment screening need label-free, real-time interaction data. This SPR analyzer offers 1–8 flow channels or arrays, affinities from about 1 mM to 10 pM, association rates of 10^3–10^7 M⁻¹s⁻¹ and baseline noise below 0.1 RU. It controls 4–40 °C within ±0.1 °C at 1–100 µL/min flow.
| Parameter | Value |
|---|---|
| Detection channels 检测通道 | 1–8 flow channels or array formats |
| Affinity range 亲和力范围 | approx. 1 mM–10 pM (analyte dependent) |
| Association rate range 结合速率范围 | approx. 10^3–10^7 M⁻¹s⁻¹ |
| Baseline noise 基线噪声 | below 0.1 resonance units (typical) |
| Temperature control 温度控制 | approx. 4–40 °C, within ±0.1 °C |
| Flow rate 流速 | 1–100 µL/min |
| Sample volume 样品体积 | 50–200 µL per injection |
| Sensor chemistry 传感表面化学 | Carboxymethyl dextran, streptavidin or capture surfaces |
| Detection 检测方式 | Angle-resolved surface plasmon resonance |
| Dimensions (W x D x H) 外形尺寸(宽 x 深 x 高) | approx. 600 x 500 x 400 mm |
| Model No. | PAN-0004 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.