Welcome to Liquid International — factory-direct lab & training equipment from China

LI-QUID LIQUID INTERNATIONAL 利奎德国际 · Shanghai
Inquiry Basket0

TOC 分析仪

TOC Analyzers

Model No. TOA-0002 · Elemental Analysis Instruments

UV-Persulfate TOC Analyzer for Ultrapure Water

超纯水 UV-过硫酸盐 TOC 分析仪

Purified water, WFI, condensate and semiconductor water need TOC measured at sub-µg/L levels. This UV-persulfate analyzer combines 185/254 nm UV with sodium persulfate at 60–100 °C, detects by long-path NDIR and reaches 0.5 µg/L. Repeatability is ≤2% CV at 100 µg/L with 4–7 min analyses. Tell us your water type.

Measurement range
0.5 µg/L–50 mg/L
Detection limit
0.5 µg/L
Oxidation method
UV (185/254 nm) plus sodium persulfate
Reactor temperature
60–100 °C
Sample volume
5–20 mL
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

Purified water, WFI, condensate and semiconductor water need TOC measured at sub-µg/L levels. This UV-persulfate analyzer combines 185/254 nm UV with sodium persulfate at 60–100 °C, detects by long-path NDIR and reaches 0.5 µg/L. Repeatability is ≤2% CV at 100 µg/L with 4–7 min analyses. Tell us your water type.

Highlights

  • Sub-µg/L detection for ultrapure water
  • Wet oxidation avoids combustion blank issues
  • Long-path detector improves low-level precision
  • Suits cleaning validation rinse samples

Applications

  • Pharmaceutical purified water and WFI testing
  • Power plant condensate monitoring
  • Semiconductor ultrapure water
  • Cleaning validation rinse samples

Specifications 技术参数

ParameterValue
Measurement range 测量范围 0.5 µg/L–50 mg/L
Detection limit 检出限 0.5 µg/L
Oxidation method 氧化方法 UV (185/254 nm) plus sodium persulfate
Reactor temperature 反应器温度 60–100 °C
Sample volume 进样体积 5–20 mL
Repeatability (CV) 重复性(CV) ≤2% at 100 µg/L
Analysis time 分析时间 4–7 min per sample
Detector 检测器 Long-path NDIR
Carrier gas 载气 High-purity nitrogen or synthetic air
Reagent consumption 试剂消耗 Persulfate and acid, about 0.5 mL per run
Model No.TOA-0002
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 8245 EN 1484 ASTM D7573 ASTM D4129 USP <643> Ph. Eur. 2.2.44 ISO 10694 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: UV-Persulfate TOC Analyzer for Ultrapure Water (TOA-0002)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.