Power-Compensation DSC for Polymer Analysis聚合物分析用功率补偿型差示扫描量热仪
- Temperature range
- −90 to 550 °C with cooling system
- Heating rate
- 0.1–200 °C/min
聚合物分析用差示扫描量热仪

Photo for reference; configuration may vary by order.
Model No. DSCA-0001 · Polymer Analysis Equipment
聚合物分析用热流型差示扫描量热仪
Our heat-flux DSC is the everyday instrument for checking melting and crystallisation points, oxidative induction time and cure of moulding compounds. With a cooling accessory it spans −150 to 600 °C, heats at 0.1–80 °C/min and cools at up to 50 °C/min with liquid nitrogen. Calorimetric accuracy is ±1% on indium.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Our heat-flux DSC is the everyday instrument for checking melting and crystallisation points, oxidative induction time and cure of moulding compounds. With a cooling accessory it spans −150 to 600 °C, heats at 0.1–80 °C/min and cools at up to 50 °C/min with liquid nitrogen. Calorimetric accuracy is ±1% on indium.
| Parameter | Value |
|---|---|
| Temperature range 温度范围 | −150 to 600 °C with cooling accessory |
| Heating rate 升温速率 | 0.1–80 °C/min |
| Cooling rate 降温速率 | Up to 50 °C/min with liquid nitrogen |
| Calorimetric accuracy 量热准确度 | ±1% (indium) |
| Temperature accuracy 温度准确度 | ±0.2 °C (indium) |
| Sensor type 传感器类型 | Disc-type thermocouple array |
| Crucible volume 坩埚容积 | 40 µL standard, 100 µL optional |
| Purge gas flow 吹扫气流量 | 20–50 mL/min |
| Typical sample mass 典型样品量 | 5–15 mg |
| Power supply 电源 | 220 V, 50/60 Hz |
| Model No. | DSCA-0001 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.