Heat-Flux DSC for Polymer Analysis聚合物分析用热流型差示扫描量热仪
- Temperature range
- −150 to 600 °C with cooling accessory
- Heating rate
- 0.1–80 °C/min
聚合物分析用差示扫描量热仪

Photo for reference; configuration may vary by order.
Model No. DSCA-0002 · Polymer Analysis Equipment
聚合物分析用功率补偿型差示扫描量热仪
Research groups working on thin films, blends and small samples choose power compensation for its fast response and sharp resolution. Twin platinum resistance thermometers allow heating at up to 200 °C/min and mechanical cooling at up to 100 °C/min across −90 to 550 °C. Calorimetric accuracy is ±0.5% and precision ±0.1%.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Research groups working on thin films, blends and small samples choose power compensation for its fast response and sharp resolution. Twin platinum resistance thermometers allow heating at up to 200 °C/min and mechanical cooling at up to 100 °C/min across −90 to 550 °C. Calorimetric accuracy is ±0.5% and precision ±0.1%.
| Parameter | Value |
|---|---|
| Temperature range 温度范围 | −90 to 550 °C with cooling system |
| Heating rate 升温速率 | 0.1–200 °C/min |
| Cooling rate 降温速率 | Up to 100 °C/min with mechanical cooling |
| Calorimetric accuracy 量热准确度 | ±0.5% (indium) |
| Temperature accuracy 温度准确度 | ±0.1 °C (indium) |
| Calorimetric precision 量热精密度 | ±0.1% |
| Sensor type 传感器类型 | Dual platinum resistance thermometers |
| Crucible volume 坩埚容积 | 20–40 µL |
| Typical sample mass 典型样品量 | 1–5 mg |
| Purge gas flow 吹扫气流量 | 10–50 mL/min |
| Model No. | DSCA-0002 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.