High-Volume PM10 Air Sampler大流量 PM10 采样器
- Measurement method
- Gravimetric, pre-weighed filter
- Size fractions
- TSP, PM10, PM2.5 (inlet dependent)
挥发性有机物分析仪

Photo for reference; configuration may vary by order.
Model No. VOA-0003 · Air Quality Monitoring Equipment
总烃分析仪
Solvent recovery units, print shops and coating lines usually face limits expressed as total hydrocarbons, and an FID gives one calibrated figure for all organics. This analyzer spans from 0–10 ppm up to 0–100,000 ppm with 0.05 ppm detection as methane and T90 under 2 s. Add the non-methane cutter if your permit asks for NMHC.
| Place of origin | China (dispatched from Shanghai) |
|---|---|
| Brand | Liquid International / OEM on request |
| Export packing | Fumigation-free plywood case or reinforced carton |
| Loading port | Shanghai / Ningbo (others on request) |
| Payment terms | T/T, L/C at sight (confirmed on quotation) |
| Trade terms | EXW, FOB, CFR, CIF, DAP |
Typical export terms — final terms are confirmed on the proforma invoice.
Solvent recovery units, print shops and coating lines usually face limits expressed as total hydrocarbons, and an FID gives one calibrated figure for all organics. This analyzer spans from 0–10 ppm up to 0–100,000 ppm with 0.05 ppm detection as methane and T90 under 2 s. Add the non-methane cutter if your permit asks for NMHC.
| Parameter | Value |
|---|---|
| Detection principle 检测原理 | Flame ionization detection |
| Measurement range 测量量程 | 0–10 ppm to 0–100,000 ppm |
| Lower detection limit 最低检出限 | 0.05 ppm as methane |
| Response time 响应时间 | < 2 s (T90) |
| Sample line temperature 采样管路温度 | 120–190 °C, heated |
| Zero method 零点方式 | Catalytic scrubber, automatic |
| Optional module 可选模块 | Non-methane cutter for CH4/THC |
| Fuel gas 燃气 | Hydrogen, 99.999% |
| Outputs 输出 | 4–20 mA, RS-485, alarm relays |
| Power supply 电源 | 220 VAC, 50 Hz |
| Operating temperature 工作温度 | 5–40 °C (sheltered) |
| Model No. | VOA-0003 |
| Place of origin | China (dispatched from Shanghai) |
Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.
Fumigation-free plywood case or reinforced carton
Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.
Shanghai / Ningbo (others on request)
Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.
Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.
Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.