For trace evolved gases, residual monomers or water and solvent release profiles, a mass spectrometer gives sensitivity FTIR cannot match. A capillary heated to 200–300 °C feeds an electron multiplier detector covering m/z 1–300 at up to 1000 amu/s. The TGA reaches 1000 °C with 2–10 mg samples.

Mass range
m/z 1–300
Coupling interface
Heated capillary at 200–300 °C
Scan rate
Up to 1000 amu/s
Detector
Electron multiplier
TGA temperature range
Ambient to 1000 °C
Inquiry Now

Packing & Shipping

Place of originChina (dispatched from Shanghai)
BrandLiquid International / OEM on request
Export packingFumigation-free plywood case or reinforced carton
Loading portShanghai / Ningbo (others on request)
Payment termsT/T, L/C at sight (confirmed on quotation)
Trade termsEXW, FOB, CFR, CIF, DAP

Typical export terms — final terms are confirmed on the proforma invoice.

Product Description 产品描述

For trace evolved gases, residual monomers or water and solvent release profiles, a mass spectrometer gives sensitivity FTIR cannot match. A capillary heated to 200–300 °C feeds an electron multiplier detector covering m/z 1–300 at up to 1000 amu/s. The TGA reaches 1000 °C with 2–10 mg samples.

Highlights

  • Detects small molecules such as water at trace levels.
  • Maps flame-retardant decomposition pathways step by step.
  • Compares how effectively different stabilisers delay degradation.
  • Balance resolution of 0.1 µg for small samples.

Applications

  • Trace evolved-gas identification in polymer degradation
  • Water and solvent release profiling
  • Flame-retardant decomposition pathway analysis
  • Residual monomer and oligomer detection
  • Comparative studies of stabiliser effectiveness

Specifications 技术参数

ParameterValue
Mass range 质量范围 m/z 1–300
Coupling interface 联用接口 Heated capillary at 200–300 °C
Scan rate 扫描速率 Up to 1000 amu/s
Detector 检测器 Electron multiplier
TGA temperature range 热重温度范围 Ambient to 1000 °C
Heating rate 升温速率 0.1–50 °C/min
Balance resolution 天平分辨率 0.1 µg
Typical sample mass 典型样品量 2–10 mg
Purge gas 吹扫气体 Helium, ≥ 99.999%
Vacuum system 真空系统 Turbomolecular pump, two-stage
Model No.TGAA-0005
Place of originChina (dispatched from Shanghai)

Applicable standards 适用标准

ISO 11358-1 ISO 11358-2 ASTM E1131 ASTM E2550 ASTM D6370 IEC 61010-1

Chinese national standards (GB/T, JJG) and international standards referenced for this product type. Test reports and certificates are supplied with the quotation on request.

Packing & Shipping 包装与运输

Export packing

Fumigation-free plywood case or reinforced carton

Every unit is power-tested before packing; enclosed in shock foam and moisture barrier; wooden cases comply with ISPM 15.

Loading port

Shanghai / Ningbo (others on request)

Full container load (FCL), less-than-container load (LCL) or air freight; complete export documentation provided.

Inquiry Now 索取报价

Complete the form below — an export engineer will send technical configurations and a formal proforma invoice within 24 hours.

Products in this inquiry: TGA-MS Coupled Analyzer for Polymer Analysis (TGAA-0005)

We reply within 24 hours (Beijing Time, UTC+8). Your details are used only to answer this inquiry.

Related products

6 models

Send your equipment list — receive a formal quotation within 24 hours

Single instruments, complete laboratories or government tenders — our export engineers prepare the configuration, proforma invoice and shipping documents.